Ground-Source Heat Pumps Explained

A ground-source heat pump, often called a geothermal heat pump, uses the ground as its heat source in winter and its heat sink in summer. Below a shallow depth, soil temperature stays remarkably stable through the year, usually in the range of 8 °C to 14 °C in temperate climates. That stability is the technology’s greatest advantage: the machine works against a much smaller temperature difference than an air-source unit, so it runs more efficiently and with less variation across the seasons.

Ground-source systems cost more to install than air-source systems, mainly because of the buried loops. In return, they offer high efficiency, quiet outdoor operation and long service life. This article explains how they work, the loop configurations available and the factors that determine whether one makes sense for a given site.

How the ground becomes a heat source

Soil stores solar energy absorbed at the surface. A few metres down, daily weather variations disappear and temperature changes slowly with the seasons. In winter, the ground is warmer than the air, so it can supply heat to the refrigerant in the heat pump’s evaporator. In summer, the ground is cooler than the air, so it can absorb heat rejected by the system during cooling.

A loop of buried pipe circulates a water-and-glycol mixture, sometimes called the ground loop fluid. In heating mode, this fluid picks up heat from the soil and carries it to the heat pump, where a refrigerant cycle upgrades it to a useful temperature. In cooling mode, the flow direction of heat reverses: the fluid carries heat from the building into the ground. The refrigerant loop itself stays sealed inside the machine; only the loop fluid travels underground. The sealed circuit is factory-charged and normally needs no attention. Where offered, R290 (propane) is a natural refrigerant with very low global warming potential; because it is flammable, charge limits and strict installation and service rules apply, so its use depends on the unit design and local regulations.

Vertical, horizontal and other loop designs

The loop is the largest and most site-specific part of the installation.

  • Vertical loops: Boreholes typically 50 to 150 metres deep, with U-tubes inserted and grouted in place. They need little land area but require drilling equipment.
  • Horizontal loops: Pipelines buried in trenches, usually 1 to 2 metres deep, spread over a large area. They are cheaper to install where land is available.
  • Slinky loops: Coiled pipe laid in narrow trenches, reducing the land area needed compared with straight horizontal runs.
  • Open-loop systems: Groundwater is drawn from a well, passed through the heat exchanger and returned to the aquifer, subject to water quality and abstraction rules.

Closed-loop systems dominate because they recirculate the same fluid and have minimal environmental interaction. The choice between vertical and horizontal usually comes down to land area, geology, drilling cost and local regulations.

Sizing and thermal balance

A ground loop must be sized to deliver the required heat over a whole season without the ground becoming too cold. The design depends on soil type, moisture content, thermal conductivity, the building’s peak load and total annual energy demand. Sandy, dry soil conducts heat poorly and needs more pipe length than damp clay or rock. Professional design uses the building’s heating and cooling loads to balance the loop so that heat removed in winter is roughly replaced in summer.

This balance matters most in buildings with very different heating and cooling demands. A heating-dominated building may gradually cool the ground over many years if the loop is undersized or summer rejection is too low. Careful sizing, and in some cases hybrid systems that add a small auxiliary heat source, prevent this long-term drift.

Efficiency and performance

Ground-source heat pumps typically achieve higher seasonal efficiency than air-source systems because the source temperature is stable and relatively warm in winter. A well-designed system can deliver strong coefficient of performance values through the heating season, with far less penalty during cold spells than an air-source unit. Cooling performance also benefits from the cool ground, reducing the energy needed for summer comfort.

Efficiency still depends on the delivery side. Low-temperature emitters such as underfloor heating or low-temperature radiators allow the machine to work efficiently, while high water temperatures reduce performance. Variable-speed compressors and circulation pumps further improve seasonal results by matching output to the load. Good building insulation lowers the demand placed on the whole system.

Because the source temperature changes little, a ground-source unit can be sized closer to the building’s actual peak load without the large safety margin an air-source unit needs for the coldest hours. This reduces the equipment’s physical size and avoids oversizing penalties. It also means performance is more predictable from month to month, which simplifies energy planning and makes seasonal efficiency easier to estimate accurately.

Installation and practical issues

Installation begins with a site survey and, where needed, a test borehole or thermal response test to measure ground conductivity. Drilling or trenching is the main cost driver and can be disruptive, so access, existing services and neighbour considerations must be checked early. The loop fluid must include antifreeze in cold climates, and the system needs an expansion vessel, circulation pump and connections to the heat pump’s plate heat exchanger.

Maintenance is modest compared with combustion equipment. The loop is sealed and largely maintenance-free; attention focuses on the heat pump itself, pumps, filters and fluid quality. There is no outdoor fan coil to defrost in winter, which removes a source of energy loss and noise.

Advantages and limitations

Ground-source systems offer high efficiency, stable performance, low noise and no need for a large outdoor unit. They work well in cold climates and suit buildings with both heating and cooling demand. Their drawbacks are high upfront cost, the need for suitable land or drilling access and a longer, more complex installation process.

YUANDING ENERGY shares this explanation to help readers weigh ground-source technology against other heat pump options. The key takeaways are below.

Conclusion

  • Ground-source heat pumps use the stable temperature of the soil for efficient heating and cooling all year.
  • Vertical, horizontal, slinky and open-loop designs suit different sites and budgets.
  • Correct loop sizing based on ground conductivity and annual loads is essential for long-term performance.
  • Higher installation cost is balanced by strong seasonal efficiency, quiet operation and low maintenance.